![]() ![]() Which saniflo system will be good to pump toilet, basin and bath waste away?Īnother problem I am having is, it will pump upwards, go thru a wall (above bedroom door) in hallway, bend it with copper 22mm and then thru the hallway at the top into the bathroo which lucky have a false ceiling which I will put thru then another 22mm machine bend accross bathroom ceiling and then other 22mm bend down about 2.5m into the soil stack with a slight offset bend into boss strap with 22mm reducer. She want us to build a ensuite within the front bedroom, hence no access to the soil pipe. Soil pipe right at the back of flat and bedroom in front of flat. I have also left a stub of pipe capped on the left, in case we decide to remodel the closet on the other side of the left wall into a shower stall with the Sanishower pump.Customer lives in a ground floor flat. A sweep tee and fixture tee combo is used to bring the p-trap opening at the right height, and also to connect a AAV (not connected yet) for sink venting. There was a stud getting in the way above, hence the sink horizontal run is at a lower level than typical sink height. On the left is the pipe for the sink drain. This is mated with a 1" to 1.5" reducer, which is then tied to a s 1.5" sweep tee, which goes to the vertical drain. If you have space to spare, close off the toilet in a separate WC or designated niche. Saniflo bathroom layout full#Put up a partition between the toilet and the rest of the bathroom try a low or angled wall, full wall, or screen. A short horizontal stub with a ball valve connects to the saniflo, before turning up (through two 45 elbows) and then turning left (again through two 45 elbows). Try one (or more) of these six tips to make your toilet practically disappear. ![]() On the right is the Sanicompact waste line. I have completed a rough in of the drain (nothing is glued yet), and would appreciate a critique before I go with it (this is my first major plumbing project) I decided to go above the junction box / conduit, since it didn't seem right to squeeze the pipe between the conduit and drywall, and the Saniflo rep got back to me saying the Sanicompact discharges at 10-15 psi, and a vertical lift should be used if some pressure drop is desired. Thanks for the advice, Tuttles and JoeJee. I'm worried about the saniflo pump shooting waste into the washbasin horizontal run in C, so am thinking D would be better (although I'd be using a sweep tee to make the saniflo connection, so it's unlikely that the flow should enter into the horizontal run for the basin with C, but since it involves poop pumped around with pressure, better to be safe than sorry). Is this correct?Ģ) When connecting into a vertical drain pipe servicing multiple fixtures (such as wash basin + saniflo), is it recommended to have the saniflo connect above (drawing C) or below (drawing D) the wash-basin (I plan to directly connect the wash basin to my drain stack and not use the wash-basin port on the sanicompact). Whether you want to add an en-suite bathroom, create a powder room or make use of a loft space, Saniflo can help you create your new dream bathroom. Looking at the output specs of the Sanicompact, it's rated for a vertical lift of 9 ft, which converting to psi puts it right around 5psi for a 9ft high water column, so I'm thinking it should be safe to use this without a vertical lift. Or is it recommended to have some vertical lift (such as drawing B) and if so, what would this minimum lift be. Given that the Saniflo has a pump, is it acceptable/safe to connect at grade to the drain pipe without a vertical lift (which would dissipate some of the output pressure). I had a few questions on the rough in for the Saniflo unit for anyone who may be familiar.ġ) Standard ABS / PVC DWV systems are rated for 5 psi. Since this is a laundry room, I do have access to a 2" drain pipe, which I plan to tie into. Specifically the Sanicompact (which is there all in one macerator unit), since the room I'm converting is also kind of small. Saniflo Homeowners Ranging from the kitchen to the bathroom and toilet area, SFA offers the possibility of creating these new spaces, anywhere, without major work. The house is on slab, so I have decided to go with a Saniflo unit as I don't want to break into the slab. I am in the process of converting a laundry room to a half bathroom. ![]()
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |